Verification

Report Verification

Confirm that a Puralytix report is genuine. Enter the unique report ID and verification key printed on the report — no account is required.

Verified — authentic Puralytix certificate

Certificate PLX-202609-50152 for batch GP26-2152 was issued by Puralytix Analytical Laboratories and has not been revoked.

ProductTB-500 (Thymosin Beta-4 Fragment)
CategoryRepair & Recovery
Strength / presentation20mg — Research Vial — Lyophilised Powder
Batch / lot numberGP26-2152
Lab report no.PLX-202609-50152
IdentityConforms to reference standard (LC-MS (ESI-Q-TOF))
Purity99.0% by UPLC — UPLC-UV, 214 nm
Peptide content101.4% of label claim (20.28 mg/vial, label claim 20mg)
[M+H]+1838.4 m/z observed vs 1838.7 m/z theoretical; [M+2H]2+ 919.9 m/z
AnalystDr. R. Okonkwo
Approved (QA)Dr. P. Achebe
Date of test5 September 2026
Date of manufacture20 August 2026
Expiry20 August 2029
LaboratoryPuralytix Analytical Laboratories
AccreditationISO/IEC 17025:2017 (ref. PLX-UKAS-8847)

Download certificate (PDF)

For Research Use Only. Not for human or veterinary use.

No customer, order or delivery information is shown on this page. Puralytix provides independent analytical information only and does not provide medical, dosing, sourcing, legal or consumption advice. A result does not imply that any substance is safe, approved, lawful or suitable for human use.

For privacy, this page never displays customer details, addresses, emails, payment data or order information.

Understanding the result

A report will return one of four statuses.

Valid

The report is genuine

The ID and key match a report we issued, and it has not been withdrawn or replaced.

Not found

No matching report

Most often a typing error in the ID or key. Check both values carefully and try again.

Revoked

Withdrawn by Puralytix

This report should no longer be relied upon. Contact us if you have been shown a revoked report.

Superseded

Replaced by a later report

A corrected or updated report has been issued for the same sample.

Why verification matters

Analytical reports are easy to alter and easy to fabricate. Verification lets anyone confirm, straight from the source, that a report was issued by Puralytix and has not been edited — while keeping the client’s identity and order details entirely private.

Verification confirms the authenticity of the document. It does not extend the report’s findings, and it says nothing about whether a substance is safe, lawful or suitable for any use.

Valid

Report ID

PHX-B1000-26

Verification key

28CB-AE18

Test category

SERM

Date issued

28 March 2026

A real, current report. Verify it yourself → or browse the public report register.

If you cannot verify a report that you believe to be genuine, please contact us with the report ID and we will investigate.
Analytical information only. Puralytix provides independent laboratory analysis and informational reports. We do not sell anabolic compounds, peptides, SARMs, SERMs, medicines, injectables or any controlled substances, and we do not provide medical, dosing, sourcing, legal or consumption advice. A result does not imply that any substance is safe, approved, lawful or suitable for human use. Clients are responsible for complying with the laws of their own jurisdiction.